Maximum Session Time
The maximum sauna session time depends on the purpose of the sauna. For domestic
use, the total on-time of the sauna is limited to 6 hours. *)It includes pre-run time
and the session time. The factory setting for the control unit is 6 hours.
For condominiums, hotels and similar locations, the operating period of the sauna
heater is limited to 12 hours, including the pre-run time and the session time.
For public sauna, the operating period of the sauna heater can be either 18 or 24
hours. Please note, if the public sauna is set to 24 hours, it will be on constantly. It
needs to be continuously attended.
The maximum heater on-time is set by the jumpers on SCB1 in the power controller,
see the Fig. 5. Jumpers 3, 4 and 5 are meant only for public sauna rooms. Only a
qualified electrical can change the settings. The standards and regulations of the
country where the control unit is installed must be followed, when setting the
jumpers. When no jumpers are placed, the default time is 6 hours. See the Table.
*) IEC 60335-2-53
Sauna Type Domestic sauna Hotels, Condominiums Public sauna
Jumper
1 2 3 4 5
4h 6h
3h 5h
12h
99h
18h 24h
Max. time
Max. pre-run time
The heater main switch can be found on the
lower part of the heater. Using this switch, you
can isolate the electronics from the mains power
supply.
In order to put the unit into operation, switch to
the first position (switch position I). In this
switch position all control units functions work
normally.
In case of breakdown, press the control unit
switch on the left part of the rocker to the
middle position (switch position 0). The unit is
now completely switched off.
In order to switch on the light in the sauna
when the unit is switched off, press on the left
part of the rocker to the second position (switch
position II).
The Heater Main Switch
0 =
=
=
II
I
OFF
LIGHT ON
UNIT ON
0II I